Melodia Professional Ver. 1.42 Copyright 1993-1994 John Dunn (S)ave to save changes; (D)iscard to discard them. (L)oad original file; (O)verwrite with current; make (N)ew. (O)K to erase the current file; (C)ancel to leave it intact. Select Midi Sync, Strt/Stop/Cont, Song# to send or receive. Unregistered Version! File Save name can not be changed. File: files & exit. Zoom: 25/50 line (VGA). Page: goto next. Dial to select clock A-L, Measure M-N. Click: M(ute), remembered by stages; S(olo), not remembered. Click to turn entire voice on or off. Dial for MIDI Program Change 0-127. Dial for Kb pitch value/conn. Also added to 2nd & 3rd Kb. Dial to select transposition value, added to all Kb outputs. Dial for note delay 0-15 (0-9, A-F). Dial for MIDI Pan Control Change value/connection. Dial for MIDI Modulation Control Change value/connection. Slide to change volume. Auto when stage changed & Slew > 0. Dial to change slew rate for auto volume change on new stage. Dial to change tempo in beats per minute. Dial to change number of beats/measure in time signature. Dial for beats in time sig. 64 = direct clock = 32nd triplets. Dial for number of measures the current stage will play. Measures played in current stage. Click to set to 0. Readout of total measures and playing time of the composition. Click to stop sound generation. Restarts sequencers from 0. Click to turn all protection from Pop, Top, & Prev on/off. Click to reset stage to values in effect when last entered. Click on/off; when on Push will also delete the current stage. Click on/off; when on Pop, Top, & Prev will insert the stage. Click to turn protection from Pop, Top, & Prev on/off. Click to copy the current stage onto the holding stack. Click to copy/remove the last stage Push to the current stage. Click to copy the last stage Push to the current stage. Click to copy the previous stage to the current stage. Click to stop the composition from playing (advancing stages). Click to start advancing stages without restarting at stage 0. Click to turn protection from Pop, Top, & Prev on/off. Click to reverse direction of Pan. Step stack depth readout. Push increments, Pop decrements. Dial beat: legato, normal, on new pitch, legato on new pitch. Click to start playing from stage 0. Halts if stage 0 M=Stop. Slide for new stage; each stage is a different page of music. Dial for MIDI Channel. Multiport: 0-15 = 1st, 16-31 = 2nd, etc. Dial for Volume value/conn. Limited by Fade value. Dial for 1st Kb Velocity value/connection. 00 turns off. Dial for MIDI Aftertouch (Channel Pressure) value/conn. Dial for Kb pitch value/conn. Added to 1st Kb if Vl = 00. Dial for MIDI Foot Pedal Control Change value/connection. Dial for MIDI Breath Controller Ctl Change value/connection. Dial for MIDI Portamento Time Ctl Change value/connection. Dial for 2nd & 3rd Kb Velocity value/conn. 00 turns off. Click for MIDI Portamento Switch Control Change on/off. Click for MIDI Sustain Switch Control Change on/off. Click to inhibit MIDI Note Off messages. Not an active area. Melodia Professional Ver. 1.42 Copyright 1993-1994 John Dunn File: files & exit. Zoom: 25/50 line (VGA). Page: goto next. Dial for note-on to delay, units = % of total note time value. Dial for note sustain time as % of total note time value. Click to turn protection from Pop, Top, & Prev on/off. Click to set R4 output scale: none, major, minor. Slide # to select sequencer step, slide green o to set end. Dial for input value/conn. Slews when stage changed. Dial for slew rate value/conn. Higher values slower, 0=off. Dial for note tick rate, 24=Quarter note, 48=Half note, etc. Dial note/conn. T=32nd, S=16th, etc.; triplet, dot, normal. Dial to select clock A-L/M/N to trigger the next value. Dial for value/conn of maximum random value; 0 for no random. Click to enable T4 to jump to step in Y if A,B are connections. Dial for value/connection to add to the output. Final value readout: Click to change between Note and Value. Dial to select clock A-L/M/N to trigger the next value. Dial for sequence step direction: off, up, dn, up/dn, random. Dial for a value/conn. for each of the 16 steps. Click to show current ends of sequences. Halt resets to 0. Dial to select clock A-L/M/N to trigger the next value. Dial for step direction: off, up, dn, up/dn, rand, rand-up/dn. Dial to select one of the 10 banks of up to 10,000 steps/bank Dial for high-order address of the current sequencer bank. Dial for low-order address of the current sequencer bank. Dial for stp size. 0 allows connection to set hi & lo address. Dial to offset (add to) current address location. Click to set current address as the end of the sequence. Readout of current value / Dial to change current value. Invert: Return normal and inverted input with scaling, offset. Dial to select clock A-L/M/N to trigger the next value. Dial to select target value/conn. of Follow tracking. Final value and inverted value readouts. Click for note/value. Switch Sequencer: Sequences up to 16 values/connections. Banked Sequencer: Sequences up to 10 banks of 10,000 cells. Limiter: Limits input by percentage or absolute ammount. Test: Tests two inputs, gives result as "Y" or "N" input. Value: Slews toward input value. Simple mixer if Slew=0. Dial to select compare test of #A vs. #B. Dial to select "A" source/connection for #A vs. #B test. Dial to select "B" source/connection for #A vs. #B test. Dial to select results returned if test answer is "Yes." Dial to select results returned if test answer is "No." Follow: Increments/decrements toward input on each clock tick. Random: Generate a random number on each clock tick. Dial to select source value/connection for limiting. Dial to set limit ammount in percent. 0=off (100%). Dial for value/connection to add to limited source. Dial for maximum allowed value at final output. Dial to select source value/connection for inverting. Dial to scale source ammount by a percentage. 0=off (100%). Dial to set center offset. 0 = none (+); 127-value (-). Dial for MIDI Channel. Multiport: 0-15 = 1st, 16-31 = 2nd, etc. Dial value/conn for Program Change. Sent on turn-on and change. Dial for value/conn of control number for MIDI Ctrl Change. Dial value/conn for Control Change. Sent on turn-on and change. Click to enable & send current MIDI Program Change value/conn. Click to enable & send current MIDI Control Change value/conn. Not an active area. Melodia Professional Ver. 1.42 Copyright 1993-1994 John Dunn Click (or ESC key) to Return to current work display. Click (or ESC key) to Exit from MIDI Paint. Click to save current work file. Click to send/receive MIDI sync and sequencer control data. Click to get Music connections from another file on next load. Click to get Bank data from another file on next load. Slide up/down to view additional filenames, if any. Click on filename to load that file into current workspace. Click, then type in a new filename to rename current workspace. When checked, files have been modified. Click to force change. Click to Erase current work file set. Click to get Bank data from a .TXT file, click again for .DNA. Click to run DOS EDIT, to create or edit a Text file. Dial for bank: from->to; click arrow to copy. A-D not saved. Not an active area.