Try to navigate by clicking items on the bitmap
Report section contains informations about converting the module
MODULE TITLE - the title of the module
NUMBER OF POSITIONS - number of positions in the 1st song
NUMBER OF PATTERNS - total number of patterns in the module (songs use the same patterns)
NUMBER OF INSTRUMENTS - number of instruments in the module (empty or not)
NUMBER OF SAMPLES - number of samples in module
Global DSP - Yes means that the module use DSP of AHI. The DSP cannot be converted, so the XM module will sound totally different than the DBM version.
Version - Shows version of DigiBoosterPro which the module is made with. The converter is designed for v2.20. Newest versions could be different (but not have to)
In the list below the programs prints information about program
jobs (ie. Preferences saved) and also about the convertion. In the
second case the most important thing is the report of convertion report. Ie.:
Pattern: 0, line: 34, track: 8 (YF0 X02)
That means, in 34th line and 8th track of pattern 0 the DSP commands are found. These will not be converted because XM doesn't support such ones.
There will be another case, ie:
Pattern: 3, line: 56, track: 2 (930 836)
930 830 will not be converted, until the FORCE atribute will be chosen in prefs section. It's impossible to convert one of these commands in VolCMD column without some loss (look at the XM format description).
There are another infos apear in this list:DSP cannot be converted! - if the module has defined the global DSP
Impossible correct conversions: - the raport about not exact or impossible conversion will be started with this one.
Songs 2 - X will be lost - where X is the last song number
Song X placed at position Y - where X is the song number and Y is the position in the module
Song X placed at position Y - looped - jw., if Join Song is set to Yes looped and looping is done
Song X placed at position Y - not looped - jw., jw., if Join Song is set to Yes looped and looping is not done
pattern: X, line: Y, track: Z, (CMD1 CMD2) - impossible correct conversion of the commands in pattern X and line Y of channel Z
Preferences loaded
Preferences saved
Wrong prefs file version. Using some defaults. - defaults will be used only for options not found in the prefs file
There is no prefs file. Using defaults
Module successfully converted
Unable to save preferences file
Logfile saved
Unable to save logfile
Module preloaded
Modue analized
This is NO DBM module - if the chosed file is not DBM module
Wrong destination path
Wrong source path
Incomplete module. Conversion aborted. - if module file is broken
Fatal error! MUI interface cannot be created - if some MUI components are missed or there is no availbable memory for opening GUI
Fatal error! There is no available memory. Aplication closed. - if no memory is availble for correct program working
At the bottom of the list two buttons are found