Q: Why should I register ?  Is there any difference between the
   registered version and the non-registered version ?
A: Telemate is not free.  You must register after the 30-day evaluation
   time period.  When you register, you will receive the registered
   version which have the ending screen removed.  And you will receive
   a registration number that will remove any annoying functions in all
   future versions.


Q: Does Telemate support expanded memory ?
A: Yes, it does.  Telemate supports up to 8M bytes EMS 3.2 or
   EMS 4.0 memory. It stores the phone directory file and the
   virtual memory file.


Q: Does Telemate support extended memory ?
A: Yes, it does.  You should install the XMS (eXtended Memory Specification)
   driver HIMEM.SYS in your CONFIG.SYS.  After that Telemate can use
   extended memory as virtual memory.  Please refer to Appendix E in
   TELEMATE.DOC for detailed description on XMS, EMS and how Telemate
   use them.


Q: Can Telemate run under DESQview/386 ?
A: Yes, it can.  In the following sample setup, the 'Memory Size'
   requirement may vary from 430 to 500 depend on the back scroll
   limit, the size of the files you are going to edit or view.

   Memory Size (in K): 470

   Writes text directly to screen.......: [N]
   Displays graphics information........: [N]
   Virtualize text/graphics (Y,N,T).....: [N]
   Uses serial ports (Y,N,1,2)..........: [Y]
   Requires floppy diskette.............: [N]

   Maximum Program Memory Size (in K)..: 640
   Maximum Expanded Memory Size (in K): 1024

   Text Pages: 1  Graphics Pages: 0

   Close on exit (Y,N,blank)........: [Y]
   Allow Close Window command.......: [N]
   Uses math coprocessor............: [N]
   Share CPU when foreground........: [Y]
   Can be swapped out (Y,N,blank)...: [N]

   Uses its own colors..............: [Y]
   Runs in background (Y,N,blank)...: [Y]
   Keyboard conflict (0-F)..........: [0]
   Share EGA when foreground/zoomed.: [Y]
   Protection level (0-3)...........: [0]

   Global parameters of interest are foreground and background
   "ticks", which are set to 4 and 3 respectively; and Optimize
   Communications, which is set to Yes.


Q: Can Telemate run under Windows/386 ?
A: Yes, it can providing you have the PIF set to

   Memory Requirements: KB Required [448]  KB Desired [512]
   Usage Controls:      [X] Full Screen   [X] Background
   Program Switch:      (*) Text
   Screen Exchange:     (*) Text
   Close Window on Exit [X]


Q: What is the correct setting for USR HST ?
A: Type the following command in the terminal.

   AT Z <cr>
   AT B1C1E1F1M3Q0V1X6 <cr>
   AT &A1&M4&K0&H1&R2&I0&B1&N <cr>
   AT &W <cr>

   Then
   1. select 19200 or 38400 baud for maximum throughput
   2. change the Modem Init string to "ATZ^M~"
   3. turn on the RTS/CTS flow control
   4. turn off the AutoBaudDetect option.

   The following is the display for the HST settings

   USRobotics Courier 14400 HST Settings...

   B1  C1  E1  F1  M3  Q0  V1  X6
   BAUD=19200  PARITY=N  WORDLEN=8
   DIAL=TONE   ON HOOK   TIMER

   &A1  &B1  &C1  &D2  &G0  &H1  &I0  &J0  &K0
   &L0  &M4  &N0  &P0  &R2  &S1  &X1  &Y1

   S00=000   S01=000   S02=043   S03=013
   S04=010   S05=008   S06=002   S07=045
   S08=002   S09=006   S10=007   S11=070
   S12=050   S13=000   S14=000   S15=000
   S16=000   S17=000   S18=000   S19=005
   S20=000   S21=010   S22=017   S23=019
   S24=025   S25=000   S26=000   S27=000
   S28=008   S38=000


Q: How can I change the size of the phone directory?
A: Run TMPHONE.EXE and select the ChangeSize item in the menu.  Then
   you can increase the size up to 1000 entries.


Q: Can I run a external program by pressing only one key ?
A: Yes, the new Hot Key macro sequence "^=" allows you to use the
   function keys as hot keys, for example  "^=DIR *.ZIP^M" will
   display all the ZIP file.


Q: Can I have more than 4 external protocols ?
A: If you specify a second "^=" in the Hot Key macro, say "^=MLINK-D ^=",
   the second "^=" will be translated to baud rate and COM port information,
   in this case the macro will be translated "MLINK-D 1200 1".


Q: My modem does not hang up right the way after I press [Alt H].  Do
   I set something wrong ?
A: You should include the macro "^#", which drop the DTR, in the Modem
   HangUp string.  Moreover, you should set the DIP switch in the modem
   such that the terminal can control the DTR.  Some modems have a AT
   command to control the DTR signal, it may be "AT &D2".


Q: How can I get rid of the menu bar and/or the status line?
A: When you execute TM.EXE, you can include the full screen option '/F'
   in the DOS command line, for example, "TM /F".  Then the terminal
   will use the whole screen.  You may use the [Alt -] key to toggle
   the menu bar and status line.

Q: Where can I reach the author?
A: You can contact the author through one of the support BBSs, CompuServe
   BIX and InterNet.

   Bulletin Board System  Phone Number  Network    Baud   Location
   ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ  ÄÄÄÄÄÄÄÄÄÄÄÄ  ÄÄÄÄÄÄÄÄÄ  ÄÄÄÄÄ  ÄÄÄÄÄÄÄÄÄÄÄÄÄÄ
   PC Connect             416-733-9052  SmartNet   14400  Toronto Canada
   Southern Reaches       519-973-9841  WWIV(5950)  2400  Windsor Canada
   SouthWest Connect      519-352-7010  SmartNet   14400  Chatham Canada
   User To User           214-492-6565  RelayNet   14400  Dallas  USA

       BIX          winfredhu
       CompuServe   [72070,3515]
       InterNet     72070.3515@compuserve.com


