Ref: 11640068 Title: Checking Tandberg Drives for Correct PROM Levels Date: 4/9/90 Copyright 3Com Corporation, 1991. All rights reserved. If you get tape media errors when running appended backups on a Tandberg tape drive, incompatibility between the Tandberg drive's revision number and its PROM version may be the problem. Tandberg rev 20 tape drives require 6.0 PROMs. Tandberg tape drives, rev 17.1 or below, require 4.02 PROMs. If a Tandberg tape drive uses rev 20 controllers with rev 4.02 PROMs, it may intermittently fail to append data in backup, or may continue backups onto a second cartridge. Also, Tandberg tape drives with 2X06 PROMS may show intermittent media errors. The problems may occur in any of these situations: 1. On a full backup with append on the first tape. (The tape already contains one good backup on it.) 2. On a full backup with append going to the second tape. (The tape already contains one good backup on it.) 3. Using 150 MB tapes with /120 command on the TAPE.SYS line in the CONFIG.SYS file. Error occurs on a full backup with append going to the second tape. These error messages may show in the BACK_LOG file: Tape drive error; miscellaneous Unrecoverable error; operation halted Tape drive error; drive fault Unable to write final tape block How to Find Revision Levels on the Tape Drive 1. PROM Revision Level The PROM rev level can be found two ways: a. Check the back side of the tape unit in case it is already written there. b. Turn off the server and take the top cover off. Pull the tape out of the tape unit server. From the front of the server looking to the left of the tape unit you will see the revision number 2X06 or 4.02 on the PROM chip. If you have difficulty seeing the PROM chip, use a flashlight to look through the holes in the top of the tape unit. 2. Tape Controller Revision Level To read the rev level of the tape unit controller card, pull the tape unit out and turn it upside down. The rev number will appear under the order number. Example: order no 966001 rev lev 17 Upgrading Your Tandberg Tape Drive 1. If you have a support contract, call 3Com Tech Support at 1- 800-876-3COM. 2. Confirm that your Tandberg tape unit has one of the following incorrect PROM-controller combinations: PROM rev 4.02 with controller at rev 20 PROM rev 2X06 with controller below rev 20 3Com Tech Support will issue a case number to authorize return of the unit. 3. Call 3Com's RMA department to arrange for the upgrade. When 3Com's RMA department receives the tape unit the PROMs will be upgraded as follows: Units with 2X06 PROM with the controller below rev 20 will receive a 4.02 PROM. Units with 4.02 or 2X06 PROM with the controller at rev 20 will receive a 6.0 PROM. Tandberg Tape Drives PROM History Before 12/87 Version 0.8 This is a beta version that should be upgraded immediately if the PROMs are at this level. There are too many problems with it to document. 12/87 Version 2X06 This version was the first customer release. Problems include media errors ("Can't find block" after 24 re-reads, and "Can't write block" after 16 retries) and append problems ("Can't append to a second tape"). 5/88 Version 4.02 This version is almost identical to the code accepted by IBM for their Tandberg drives. It is not compatible with hardware at rev 20 or above; there are problems appending to the same tape. With hardware below rev 20 there are no known problems. 1/89 Version 6.0 This version fixes a problem created by Tandberg's hardware rev 20. If used with hardware below rev 15, the drive will make a ratcheting sound or will not work. With hardware at rev 20 or above, there are no known problems.