Ref: 02550004 Title: Differentiating Between IB/3s with MCPU-10 and MCPU-20 Processors Date: 01/24/90 Copyright 3Com Corporation, 1991. All rights reserved. Currently, IB/3s are shipped with MCPU-20 processors. In the past, to provide an inexpensive upgrade from a GS/3 or a GS/3-M (the first remote IB built upon a GS/3 platform), 3Com provided a firmware- and software-only upgrade. After the upgrade was installed, the unit was an MCPU-10 or MCPU-12 based IB/3. This article explains the difference between the two types of IBs and warns of incompatibilities between some versions of software. MCPU-10 or MCPU-12 Based IB/3: Runs SW/IB3 Version 10000 (ONLY!) - SW/IB3 Version 10000 is 83-0142-00, the Topsoft is 21-0075-00; both are obsolete, but replacement copies of the software are available from 3Com's RMA department. Must have, except where noted, the specified firmware with the boards listed below. When two firmware part numbers are shown separated by a "/", both pieces of firmware are required. Board and Part Number Firmware and Part Number --------------------- ------------------------ MCPU-10 (06-0008-02) M1MMON Rev.02B (36-0004-18/19)* or MCPU-12 (06-0008-05) IEC/M aka EC/2 (06-0021-00) M1EC2B Rev.01A (36-0005-37/38)* SIOs** M1SYNC Rev.01G (36-0005-33/34)*** ITC/M (06-0051-00)** (No PROMs needed) Both the MCPU-10 or MCPU-20 and an IEC/M must be installed in an IB/3 running SW/IB3 Version 10000, which is the last version of software scheduled for MCPU-10 or MCPU-12 based IB/3s. * Both the M1MMON Rev.02B (36-0004-18/19) and the M1EC2B Rev.01A (36-0005-37/38) are obsolete, but are available from 3Com's RMA department. ** SIO Modules that may be installed include the SIO-SMS, SIO-422S, and SIO-V.35S. The ITC/M is a T-1 Controller and, if present, is installed in one of the slots E through H in the Series/1 Chassis. See the Internetwork Bridge Installation and Operation Guide for more information. There are limits on the number of SIOs and ITC/Ms that may be installed in MCPU-10 or MCPU-12 based IB/3s. *** Rev.01G is the current revision of M1SYNC EPROMs; an IB/3 running SW/IB3 may have M1SYNC Rev.01D or later installed in its SIOs. MCPU20-Based IB/3s Must have, except where noted, the specified firmware with the boards listed below. Board and Part Number Firmware and Part Number --------------------- ------------------------ MCPU-20 (06-0044-00) M3MMON Rev.00J (36-0008-00)* IEC/M aka EC/2 (06-0021-07)** M1IECM Rev.02A (36-0005-35/36)** SIOs*** M1SYNC Rev.01G (36-0005-33/34)**** ITC/M (06-0051-00)*** (No PROMs needed) The MCPU-20 has a 68020 CPU clocked at 16 MHz. Software that may be run includes SW/20-IB Versions 10000, 11000, and 2.0 (or later). * MCPU-20 based IB/3s running SW/20-IB Version 10000 may have M3MMON Rev.00D EPROMs installed; all later versions require M3MMON Rev.00J or later. ** The installed IEC/M may have part number 06-0021-03, 06-0021-06, or 06-0021-07, but must have M1IECM Rev.02A EPROMs installed unless the IB/3 is running SW/20-IB Version 10000. If running SW/20-IB Version 10000, the IEC/M may have M1EC2B Rev.01A P/N (36-0005-37/38) installed; SW/20-IB Version 11000 and 2.0 or later require that M1IECM Rev.02A or later be installed in the IEC/M. A Broadband Controller (IBC/M) may be installed in place of the IEC/M for broadband applications; see the Internetwork Bridge Installation and Operation Guide for more information. *** SIO Modules that may be installed include the SIO-SMS, SIO-422S, and SIO-V.35S. The ITC/M is a T-1 Controller and, if present, is installed in one of the slots E through H in the Series/1 Chassis. See the Internetwork Bridge Installation and Operation Guide for more information. **** Rev.01G is the current revision of M1SYNC EPROMs. MCPU-20 based IB/3s may have M1SYNC Rev.01D EPROMs installed if running SW/20-IB Version 10000; all later versions require M1SYNC Rev.01G or later. SOFTWARE INCOMPATIBILITIES 1. SW/20-IB Version 2.0 or later requires that an IB/3 attached by serial link to an IB/3 with Version 2.0 or later, also run Version 2.0 or later. Otherwise, the IB/3s may indicate that the line is up and the other end is reachable but may fail to pass user data. 2. To keep up a serial line between an IB/3 running SW/20-IB Version 11000 and an IB/3 running SW/20-IB Version 10000 or SW/IB3 Verison 10000, set the ErrorRate parameter (available in 11000) for the path connecting the two IB/3s to 100.