Errors in the CS1x DataList ~~~~~~~~~~~~~~~~~~~~~~~~~~~ During the creation of the CS1x Editor, I had to refer to the CS1x Data List Book quite often. I encountered some errors in the list. You can find corrections for these errors here. The CS1x Editor uses these corrected values. If you know of more errors in the Data List, please let me know! ---------------------------------------------------------------------------------- *** Page 24, Table <1-7> (Effect Type List) ---------------------------------------------------------------------------------- The effects 'Flanger' and 'Phaser' have the wrong LSB numbers. They should be: TYPE MSB TYPE LSB DEC HEX 00 01 02 08 067 43 -- [10] Flanger2 [09] Flanger1 [11] Flanger3 072 48 [35] Phaser1 -- -- [36] Phaser2 (Note: The Flangers are in the list two times. Both should be as described here.) ---------------------------------------------------------------------------------- ---------------------------------------------------------------------------------- *** Page 24, Table <2-2> (CS1x System) ---------------------------------------------------------------------------------- The default controller number for knob 1 to knob 5 are wrong. They should be: ADRESS(H) SIZE(H) DATA(H) Parameter Name Description DEFAULT(H) 50 00 0F 1 0...5F Knob 1 Control Number 0...95 49 (not 4A) 10 1 0...5F Knob 2 Control Number 0...95 48 (not 47) 11 1 0...5F Knob 3 Control Number 0...95 11 (not 49) 12 1 0...5F Knob 4 Control Number 0...95 4A (not 48) 13 1 0...5F Knob 5 Control Number 0...95 47 (not 11) 14 1 0...5F Knob 6 Control Number 0...95 12 (okay) ----------------------------------------------------------------------------------